Product Description

 

 

To Maximize the capabilities of the MFM300 - GET IT ALL! 

Download the instruction manual here.

Assists in determining system efficiency
Instantly displays psychrometrics
Perform basic air balancing
Expands MFM300 capability to include humidity and psychrometric readings.
Instantaneously calculates superheat/sub-cooling as pressure and temperature change.
Speed & accuracy improved greatly over traditional analog gauge sets.
Perform Superheat / Sub-cooling simultaneously.
Eliminates manual input of pressure readings.
Superheat / Sub-cooling instantaneously calculated as pressure and temperatures change.
Compatible with all common refrigerants (Additional refrigerants available.)

The Cooper-Atkins MFM300 measures Temperature, Temperature Differential, Humidity, Dry-bulb, Pressure, Superheat, Sub-cooling and more!  The memory is loaded with 15 different refrigerant charts and has the capacity to add new and different refrigerants at a later date. Displays Min, Max and Average values. As shown, the standard unit includes one each model 1075 & 4011 temperature probe. Choose the 500 or 1000 PSI rated pressure probe in order to directly read super-heat and sub-cooling. (Pressure may also be entered by user to calculate Superheat or Sub-cooling)  To measure super-heat, just attach the temperature probe to the system suction line near the compressor, then attach the pressure transducer to the system access port near the low side of the compressor. Sub-cooling is measured in the same way, except the temperature probe is attached to the liquid line, and the pressure probe is attached to the high side access port. The MFM300 will determine if the reading is super-heat or sub-cooling and will display the appropriate label. RH Probe and Pressure Probes may be added as needed - See the options below.    

Lighten your load and increase your capabilities by using the MFM300. It's your choice …use the following instruments and tools: Digital Thermometers, Anemometers, Sling Pyrchrometers, Data Loggers, Gauge Sets, P-T Charts and Psychrometric Charts or just use one,.... the MFM300. The MFM300 has te ability to measure, calculate and display the following: Temperature - 3 zones, Delta T, Min, Max and Average; Pressure; Superheat and Sub-cooling; Psychrometrics; Air Flow; Data Logging and is Upgradeable. The MFM300 is designed as a modular, upgradeable and expandable system allowing the user to add as needed; probes; features and capabilities. Eliminates Cost!

MFM300 Specifications

Temperature:
Temperature Measurement Range:    -58 to 302F
Accuracy:   +/- 0.3% reading
Temperature Display Resolution:    0.1 degree 

Humidity:
Relative Humidity Measurement Range:   0 to 99%RH
Accuracy:   +/- 2% RH
Relative Humidity Display Resolution:   1% RH
Dry-bulb Temperature Measurement Range:    -40 to 185 F
Accuracy:    +/- 0.3% reading
Dry-bulb Display Resolution:    0.1 degree

Pressure:
0 to 500 PSI accuracy:    +/- 1% Full-Scale
0 to 1000 PSI accuracy:    +/- 1% Full-Scale

MFM300:
Ambient Operating:    32 to 120 F,  10 to 90 % RH, non-condensing

Power:
Power source:    (4) AA alkaline batteries
Battery life:    100 hours minimum


MFM300-Kit 4 Contains:
    MFM300 Multi-Function Expandable Instrument
    1075 General Purpase Temperature Probe
    4011 Pipe Strap Temperature Probe
    5029 Humidity Probe
    5400 Vane CFM Thermo-Anemometer
    5200 Pressure Probe (0 to 1000 PSI)
    5250 Pressure Probe (0 to 500 PSI)
    Heavy Duty Carry Case with detachable strap


Free!- Download the MFM300 Toolbox by clicking Here! Save it to your PC.  PLEASE close all other applications before installing the Toolbox.

Download the instruction manual here.

Warranty Information

Two Years for the meter, one year for the probes